Building Specifications
|
Item Description |
Building A |
Buildings B, C & D |
|
Property Address: |
7001 Burleson Road |
4101 Smith School Road |
|
Building Size: |
70,025 sf |
108,800 sf each |
|
Completion Date: |
Spring 2009 |
September 2008 |
|
Site: |
7.70 Acres |
26.12 Acres |
|
Legal Description: |
Lot 1 of Block A out of Telecom Office Park Final Plat. Doc #200100308 |
Lot 2 of Block A out of Telecom Office Park Final Plat. Doc #200100308 |
|
Zoning: |
Light Industrial |
Light Industrial |
|
Parking: |
350 spaces (5.0 per 1,000 sf) |
500 spaces (1.5 per 1,000 sf) |
|
Clear Height: |
24 feet |
24 feet |
|
Bay Depth: |
130 feet |
160 feet |
|
Column Spacing: |
40 ‘ x 42’ |
40’ x 40’ |
|
Loading: |
7- 10’ x 10’ dock-high doors |
17- 10’ x 10’ dock-high doors |
|
Personnel Doors: |
4 - 3’0” doors |
7 - 3’0” doors |
|
Storefronts: |
Aluminum window system with Low-E insulated glass |
Aluminum window system with Low-E insulated glass |
|
Life Safety Sprinklers: |
NFPA 13 Class 4 wet-pipe system serving the entire building |
ESFR wet-pipe system serving the entire building |
|
Structural System: |
Architectural site-cast tilt wall panels supporting 12” steel roof-joist system |
Architectural site-cast tilt wall panels supporting 12” steel roof-joist system |
|
Electrical System: |
277/480 volt, 3-phase 1,200 amp service |
277/480 volt, 3-phase 1,600 amp service per building |
|
Roof System: |
Mechanically attached TPO system, 45 mil thick on 1½ “ rigid insulation. R-9 value. |
Mechanically attached TPO system, 45 mil thick on 1½ “ rigid insulation. R-9 value. |
|
Floor Slab: |
5” slab, 3,000 psi concrete with #3 reinforcing steel |
5” slab, 3,000 psi concrete with #3 reinforcing steel |